3D transvaginal ultrasound diagnosis of uterine septa according to different classifications: are there other measurements that correlate to reproductive outcome in small indentation length?
PDF
Cite
Share
Request
Original Articles
VOLUME: 14 ISSUE: 2
P: 129 - 138
June 2022

3D transvaginal ultrasound diagnosis of uterine septa according to different classifications: are there other measurements that correlate to reproductive outcome in small indentation length?

Facts Views Vis ObGyn 2022;14(2):129-138
1. Department of Surgical Sciences Obstetrics and Gynecology Clinic, University of Rome “Tor Vergata”, Rome, Italy
No information available.
No information available
PDF
Cite
Share
Request

Abstract

Background

High discrepancy between current classifications was observed in the definition of uterine septa, especially for indentation lengths >5 <10mm.

Objectives

To assess the discrepancy between current classifications in the diagnoses of septate uterus and to correlate them with reproductive outcomes; to detect 3D transvaginal ultrasound (TVS) additional measurements, which can better correlate small indentation lengths >5 <10mm to reproductive failures.

Material and methods

Observational study enrolling 664 women of reproductive age with 3D ultrasound diagnosis of an indentation length ≥3mm. For each patient a detailed reproductive history was taken before performing 3D transvaginal examination. Patients with previous uterine surgery or metroplasty were excluded.

Main Outcome Measure(s)

Indentation lengths >5 <10mm showed high discrepancy in the diagnosis of uterine septum between different classifications. For these small indentations additional 3D measurements (indentation angle, septal width and septal length/ fundal myometrial thickness (L/M) ratio) were correlated to infertility and recurrent miscarriage.

Results

Among the cohort, 215 patients showed an indentation length >5 <10mm; 136 tried to conceive: 69 (51%) were infertile, 38 (28%) had recurrent miscarriages (≥2) and 5 (4%) had at least one delivery. Recurrent miscarriage significantly correlated to an indentation angle >134°; whereas infertility to an indentation width <32mm and a L/M ratio >75%.

Conclusions

Wide discrepancies between different classifications are more evident in indentation lengths >5 <10mm. Additional measurements on 3D coronal section may help to evaluate the risk of infertility or recurrent miscarriage.

What is new? Additional 3D TVS measurements, beyond septal lengths, in particular for small fundal indentation, may help in predicting the risk of developing adverse reproductive outcomes.

Keywords:
uterine congenital anomalies, septate uterus, 3D transvaginal ultrasound, infertility, recurrent miscarriage